BOOM LIFT MODELS X23J

JLG

X23JR0620113

If the operator attempts to start one of the two motors while the other one is already run‑
ning, the ignition does not happen and the icon indicating motor already active appears
in the display centre.

Operate on the remote control button to start the engine

THE ENGINE MUST ALWAYS BE STARTED UP WITH ALL BUTTONS AND CONTROL
JOYSTICKS IN THE NEUTRAL POSITION.
Always check that there are no foreign elements (e.g. branches) that accidentally activate a
control. The platform could move unexpectedly independently from the will of the operator
and cause serious damage/injury to objects and/or persons.
Check that all manual controls of the proportional coils are at rest.

6.4.4 S

TOPPING THE ENGINE

/

MOTOR

To turn‑off the engine press again button no. 11 of the remote control, which allows the tur
ning off or the ignition of the engine depending on whether it is already running or resting.
To turn‑off the electric motor operate as above on button no. 12 which allows the turning off
or the ignition of the electric motor depending on whether it is already running or resting.

6.4.5 S

TOPPING THE MOTOR LITHIUM VERSION

To switch off the electric motor, release the button or the lever on the remote control or relea‑
se the emergency control key.

The motor will stop automatically in 3‑4 seconds.

The electric motor can only be considered stopped if one of the emergency stop buttons
on the machine is pressed.

Whenever a movement of the machine has been completed and work needs to continue
with the machine off, one of the emergency stop buttons must be pressed and left activa‑
ted.

The machine must not be left off with the electronic board and the remote control powered.