JLG X23J Operator Manual User Manual

Page 47

Advertising
background image

43

3.5 O

UTRIGGERS POSITION MICRO SWITCHES STANDARD VERSION

The position of the outriggers and their contact with the ground is detected by 4 pairs of
micro switches positioned in proximity of the outriggers orientation joints and the outrigger
cylinder rod fixing pin.
SEE PHOTO
The micro switches positioned on the joints must be released when the outrigger is in the sta‑
bilisation position (about 58° with respect to machine axis)and pressed when the outrigger is
in the remaining positions until it reaches the transport position parallel to the machine axis.
The micro switches fixed onto the outrigger must be released when the outrigger rests on the
ground. Control the correct functioning of the micro‑switches daily.

VERSION WITH VARIABLE STABILIZATION AREA

The machines with variable sabilization area, in addition to the
above described, are equippeed with four microswitches which con‑
trol the position of the outriggers, total or reduced area, and based
on this allow or limit the rotation of the aerial part of the machine.
They are also equipped with a sensor which controls the angular
position of the aerial part compared to the the undercarriage part of
the machine.

The checking of the correct functioning of the four microswitches
is compulsory before every stabilization of the machine, in order
to do this operation position one outrigger in reduced stabilization
area and the other three in total area and check that on the remote
control appears the reduced area icon, repeat this operation for
every outrigger.

Check the correct positioning of the microswitches at every use, as indicated on the decal
positioned on the machine.

BOOM LIFT MODELS X23J

JLG

X23JR0620113

Advertising