Before this:

a)

Make sure that the features of the electric line correspond with the voltage and the fre‑
quency indicated on the electric engine plate.

b)

Check the status of the electric power supply wire and its section, which must be suita‑
ble for the power of 2.2kW. Use a “3x2.5mm2” three‑polar cable for the connection with
F47 earth socket, double isolation with 16A plug. The maximum length of the cable must
be 10 m.

c)

Insert an earth discharger into the ground and connect it to the earth clamp of the machi‑
ne (see photo) or check the efficiency of the connection network if the ground does not
allow this operation (e.g. inside rooms).

Make sure that all emergency stop buttons are released. This condition is visible on the
remote control display by verifying the absence of the relevant icon in position 7. If a
start‑up is tried with an emergency stop button not released, an error message will
appear on the display when the start button is pressed.