JLG X23J Operator Manual User Manual

Page 99

Advertising
background image

95

BOOM LIFT MODELS X23J

JLG

X23JR0620113

The good fruition of the self‑levelling is visualized in a display visible for a few seconds.

After the end of the procedure, always control that the spirit level is in the green zone. If this
does not occur contact JLG after sales service.

If during the lowering phases one of the outriggers should not come into contact with the
ground, the machine will continue to operate on the cylinder at end run until the engine
switches off or the self‑levelling cycle ends. This situation is normal and index of the fact that
the slope on which the machine is found exceeds the admitted limit for the stabilization. If,
at the end of the stabilization phase, the machine is to be lifted even further from the ground,
a new self‑levelling phase can be performed.
NOTE: the use of self‑levelling does not jeopardise the use of the outriggers in manual mode.

• SELF‑DESTABILIZATION

Press and hold button no. 1 of the remote control.

The 4 outriggers will start to lower the machine and they will completely close.
The end of the self‑destabilization cycle is visualized in a display visible for a few seconds. If
the OK display should not appear, the self‑destabilization may however be considered com‑
pleted once all the 4 outriggers are completely lifted and therefore the relevant cylinders are
at end run.

In case of complications during the operations, in both the procedures, immediately relea‑
se the selected button and all the movements will be blocked.
Stabilizing the machine
with a inclination degree higher than the one admitted may cause instability of the machine