JLG X23J Operator Manual User Manual

Page 82

Advertising
background image

6.4.2 S

TARTING THE PETROL AND DIESEL ENGINE

Before starting the engine:

Be aware of and have all procedures clear that are described in the machine and engine
USE AND MAINTENANCE MANAUL supplied and know the meaning of the safety
adhesive stickers.

Examine the Safety Standards summary table for the operator in the manual and have
applied all provisions.

Make sure that the tank cap is properly fastened.

Make sure that there are no residues of petrol or inflammable material in proximity of
the exhaust or other areas subject to overheating.

Make sure that no one stops in proximity of the machine.

Make sure that all emergency stop buttons are released. This condition is visible on the
remote control display verifying the absence of the relevant icon in position 7. When
trying start‑up with an emergency stop button not released, an error message will
appear on the display when the start button is pressed.

Engine start‑up can take place from the ground using the engine ignition key or directly
from the remote control. In this case, it is necessary to position the engine ignition key at
the ON position before climbing into the cage using the ladder and the appropriate hand
rail in order to access the control position.
Then act on the remote control button to start the engine.

The starter for the petrol engine is automatic.

For the diesel engine it is possible to control the electrode pre‑heat from the key or the
remote control.

If the operator attempts to start one of the two motors while the other one is already run‑
ning, the ignition does not happen and the icon indicating motor already active appears
in the display centre.

BOOM LIFT MODELS X23J

JLG

78

X23JR0620113

Advertising