JLG X23J Operator Manual User Manual
Page 132
7.7 P
ERIODIC MAINTENANCE LIMITS
H
ONDA PETROL ENGINE
* First intervention.
** Anyway every 3 months.
*** Anyway every 5 years.
# Anyway every year. If the tightening is not correct replace the nuts with two new with the
same specifications and restore the connection without using oil or grease.
As regards complete service of the engine, see the manual supplied by the engine manufac‑
turer or download it from the website: www.honda‑engines‑eu.com
BOOM LIFT MODELS X23J
JLG
128
X23JR0620113
DETAIL
INTERVENTION
BEFORE
START‑UP
ACCORDING
TO NECESSITY
INTERVAL (HOURS)
10
50
100
250
500
1000
2000
AIR FILTER
CONTROL, CLEANING
•
REPLACEMENT
•
ENGINE OIL
CHECK LEVEL
•
•
REPLACEMENT
•
*
•
SEDIMENT BOWL
CLEANING
•
FUEL TAK AND NET
CLEANING
•
HYDRAULIC
OIL
CHECK LEVEL
•
REPLACEMENT
•
HYDRAULIC OIL
FILTER
CARTRIDGE
REPLACEMENT
•
*
•
ARTICULATED JOINTS
GREASING
•
*
•
BATTERY
CHECK ELECTROLYTE
LEVEL
•
GEARBOX OIL
CHECK LEVEL
•
REPLACEMENT
•
*
•
MACHINE
GENERAL ERIODIC
CONTROL
•
•
*
EXTENSION ROPES
AND PULLEYS
CHECK WEAR
•
**
•
*
REPLACEMENT
•
***
COUPLING ELEMENT
SCREWS TIGHTNESS
CONTROL
•
*
•
NUT FIXING PINS
BASKET
CHECK TORQUE
200 Nm
•
#