• Minimum equipment required
‑ Class D fire extinguisher
‑ Eye protection or face shield
‑ Respirator with filter for hydrochloric acid and sulphur dioxide
‑ Neoprene gloves
‑ Acid‑resistant lab coats
‑ Baking soda, calcium oxide or acid absorbent in kit form
‑ Vermiculite
‑ Plastic bags

• Procedure
In the event of electrolyte release from the cells, proceed as follows:
‑ Evacuate the people exposed to fumes from the area.
‑ Air the environment until the complete removal of the cell and until the characteristic
pungent odour has disappeared.
‑ If the cell is too hot, allow it to cool to ambient temperature before handling it.
‑ Wear safety equipment: coat, gloves, mask and filters, and move the cell to a well‑ven‑
tilated area.
‑ Place every cell in a sealable plastic bag and remove the excess air, then seal the bag.
‑ Place a cup of vermiculite in a second bag, place the first bag in the second and seal it.
‑ Place everything in a third bag with some soda and seal the bag.
‑ Absorb and collect the leaked electrolyte with absorbent material or soda.
‑ Place the absorbent material in a bag and seal it.
‑ Clean the area with plenty of water.
‑ Dispose of the hazardous material in accordance with the local legislation in force.

• First aid in the event of contact with the electrolyte
EYES
Immediately wash the eyes in abundant running water for at least 15 minutes, keeping
the eyelids open and flushing the eye and back of the eyelid. Immediately seek medical
help.
SKIN
Wash in cold water under a shower, remove contaminated garments. Continue washing
for at least 15 minutes. Seek medical help where necessary.
RESPIRATORY TRACT
Move the casualty outdoors into the open air. If the casualty has difficulty breathing,
have oxygen administered by trained personnel. If breathing stops, apply mouth‑to‑
mouth resuscitation and immediately seek emergency medical help.