41

3.1 B

ATTERY CUT

OUT

This device, positioned on the left side of the electric components box allows to cut‑off the machine
electric circuit, blocking any movement. It is well‑visible and easily accessed without the use of
tools. It has to be activated only in case of prolonged machine down time or maintenance
assistance.
By turning the key in a clockwise direction the machine’s electric circuit is closed, while tur‑
ning it in an anti‑clockwise direction the machine’s electric circuit is cut‑off and the key can
be removed.

B

EFORE DISCONNECTING THE BATTERY THROUGH THIS DEVICE

,

MAKE SURE THAT THE ENGINE KEY IS

IN

OFF

POSITION

,

AND THE REMOTE CONTROL AND ELECTRIC BOARD ARE COMPLETELY TURNED OFF

.

3.2 D

ISTRIBUTORS OVER

PRESSURE VALVES

All platform distributors have an over‑pressure valve that limits the pressure that can be rea‑
ched inside the calibration pressure plant of the valve itself.
These valves are calibrated in the platform inspection phase by qualified staff working and
must not be tampered with for any reason.