7.25.2 R

E

CHARGING THE BATTERY THERMIC VERSION

The battery must be re‑charged in a ventilated environment away from naked flames or
possible sources of sparks.

Do not remove cables with the engine running.

The machine has an internal battery charger. To re‑charge the battery, connect the machi‑
ne to the mains electricity and activate the appropriate switch (photo).

Before connecting the machine to the electrical mains:

Make sure that the battery cut‑off is not disconnected.

Alternatively, the battery can be re‑charged as follows:
1)

Disconnect the machine electric plant terminal clamps from the battery poles.

2)

Remove lid “A” (fig.1).

3)

Connect the cables of the appliance to be re‑charged to the battery poles and start‑up the
former.

4)

When charging has been concluded, disconnect the appliance before disconnecting it
from the battery.

5)

Restore clamp fixing to the poles of the battery and then spread pure Vaseline or other
appropriate protections on them.

6)

Close the battery using lid “A” (fig.1).

The re‑charge voltage must never exceed 14.7 Volt and the load intensity must be
limited to 0.2% of the value indicated on the lid.