FAULT CODES BATTERY CHARGER
When the alarm appears and the battery charger flashes with a yellow led.
BOOM LIFT MODELS X23J
JLG
X23JR0620113
ALARM
DESCRIPTION
STOP
CHARGING
LOGIC FAILURE #1
Problem in the current circuit
Yes
CAN BUS KO
Problem in the CAN communication
No
WATCHDOG
Problem in the battery charger logic
Yes
HIGH TEMPERATURE
BATTERY
Battery temperature over 55° C
Temporary
OVERCURRENT
Anomalous absorption of input current
Temporary
HIGH TEMPERATURE
High Internal temperature
Yes
MISMATCH VOLTAGE
Problem in the voltage circuit
Yes
TIMEOUT
Phase 1 finishes for timeout
Yes
OVER DISCHARGE
Battery very discharged
No
DEEP DISCHARGE
Battery discharged deeply
No
BATTERY DISCONNECTED
Battery disconnected during recharge
Temporaire
PUMP MISTAKE
Possible slowdown of the air pump
No
TH. SENSOR KO
Problems in the thermal probe
No
LOGIC FAILURE #2
Lowerings
Temporaire
FLASH CHECKSUM
Error in the flash memory
Yes
EEPROM KO
Problem in the EEPROM communica‑
tion
Yes