2N M2M Solution 2N SmartCom - User Manual 1.9.0 User Manual

Page 102

Advertising
background image

102

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Caution

Important! A change of these parameters will affect the server
function directly. Remember the changed values for later use. For
example, if you change the

, you will have to enter a new

Listen Port

port during login. If you forget it, you will have to reinstall the whole
server!
The web interface connection is only possible from the IP
addresses from which the terminal or Control Panel were
connected.
Any other connecting attempts will be rejected to avoid
server violation.

The other part does not affect the server function. You can modify the

settin

Log level

g, which is a digital value specifying how detailed the LOG file should be. The setting
options are 1 – 5. The default value is 3.
The

and

items are automatically set to the

Max user

Terminal TCP connections

highest possible value according to the licence. Enter the required count of connections
if necessary. If you exceed the licence limit, the application will automatically limit your
selection to the upper limit allowed in the licence.
Also, set the

packets. The default value is an optimum solution and need

Keep Alive

not

be

changed.

Should

problems

occur

with

the

NAT

use

on

application–server–terminal route, lower the time values. The Application data

parameter shows the path to the directory where the

Serv

directory

2N SmartCOM

®

er saves the LOG files and is for information only.

Note

The Application data directory shows the location of the server LOG

files. Hence, it is only in the PC on which the

Server

2N SmartCOM

®

is installed. You will not find this directory on the PC from which you

launch the

Control Panel and log in to the

2N SmartCOM

®

2N

®

Server remotely!

SmartCOM

Default Terminal Firmware URL is the address that can be used for firmware
upgrade for the terminals. This firmware corresponds to and is fully compatible with

the version of your

Server and Control Panel.

2N SmartCOM

®

Caution

Remember to keep the firmware address format. The currently valid
address is available in the Server settings menu. If you enter this
link into the terminal, the terminal will replace the sequence of
characters '$(SERVER_IP)' with the address of the currently connected
server.

The non-editable column to the right includes information on the server to which you
are connected such as serial number, licensed hours, maximum counts of users and
terminals, upgrade enable/disable and AT API functions. It also shows the remaining
server operation hours and the current server time.