3.1 Putting in Operation

Operational state is

's main function. In this state, periodic data

2N SmartCOM

®

readouts from input circuits are made.

responds to queries from the

2N SmartCOM

®

superior data concentrator, which can be the

server, monitors the

2N

SmartCOM

®

events on the RS-232 / 485 / M-Bus interfaces and sends the acquired data to the
server via GPRS, or Ethernet in the case of the PRO ETH version.

Initialisation

Insert the PIN–disabled data SIM card in

and connect the GSM

2N SmartCOM

®

antenna and power supply as instructed in

., Mounting.

Subs. 2.3

When the

power supply is connected, the LED indicator on the upper

2N SmartCOM

®

side of the module flashes three times quickly and then starts flashing in longer
intervals. Refer to

. for LED status details. The GPRS module starts

Subs. 3.2

communicating with the provider in about 10 seconds trying to log in and obtain the IP
address. The LED starts shining constantly to indicate a successful login.

Tip

2N SmartCOM

®

is working if the LED indicator is shining, thus

indicating a successful mobile provider connection and IP address
assignment.

To identify the

IP address assigned by the mobile provider or perform

2N SmartCOM

®

the basic configuration upon power up, get connected via the serial port (RS 232). The
port is in the data mode upon power up, retransmitting all data from the input to the
GPRS network. Use the +++ sequence preceded and followed by a 1–second delay to

switch into the configuration mode. When your

replies OK, start

2N SmartCOM

®

configuring using the AT commands as listed below.

Restart the serial port to return to the data mode. To do so, you can either send the

ATO command or disconnect

from the power supply.

2N SmartCOM

®

Tip

can also be configured via Terminal Config. Refer to

2N SmartCOM

®

.

S. 6
If you cannot use a PC, make the basic settings using SMS messages.
Refer to

for details.

S. 5

When your

has been programmed as required, connect the device to

2N SmartCOM

®

the available serial ports RS-232 / 485 / M-Bus. Launch the hyperterminal and get

connected to the

public IP address via port 10000, which, together

2N SmartCOM

®

with the serial port, can be used for configuring. Use port 10001 for retransmitting data
to RS-232 and port 10002 for retransmitting data to RS-485 / M-Bus.