ZigBee (for 2N SmartCOM PRO Only)

®

These commands are available in the

and

2N SmartCOM PRO

®

2N SmartCOM PRO

®

versions only, which are equipped with an optional ZigBee module. You can define

ETH
up to 16 devices to be saved in the database and communicated with.

at^sczb="add",<16 HEX>

Enter the command to add a device to the table. "<16 HEX>" is a 16-character
IEEE address. Contact your meter manufacturer for these parameters.

Tip

The IEEE ZigBee addresses have the following format: 00:15:

. The AT command for adding a device with the

bc:00:1d:00:0e:c5
selected address is as follows:

at^sczb="add",0015bc001d000ec5

The command adds the device to the first vacant place in the table.

at^sczb="del",<dev_id>

Enter the command to remove a device from the table. Setting options: 1 - 16.

at^sczb="onoff_get",<dev_id>

Enter the command to write out the state of the relay with the selected ID.

at^sczb="onoff_set",<dev_id>,<state>

Enter the command to set the selected relay state for the device with the
selected ID. 'dev_id' specifies the meter position in the table and 'state' (0/1)
defines the relay state (OFF/ON).

at^sczb="metering_getactive"

Enter the command to read out the current immediate consumption from the
meter with the selected ID.

at^sczb="metering_getsumt"

Enter the command to read out the current total consumption from the meter
with the selected ID.

at^sczb="module_type"

Enter the command to display information on the ZigBee module. Response
example: ^SCZB: "MODULE_TYPE","RC2400,2.01,"

at^sczb=?