Real time clock, Wireless m–bus interface – 2N M2M Solution 2N SmartCom - User Manual 1.9.0 User Manual

Page 25

Advertising
background image

25

2N TELEKOMUNIKACE a.s., www.2n.cz

®

Real Time Clock

This function is available in the

version only. The real time clock

2N SmartCOM PRO

®

is backed up by a super capacitor, which keeps it running for 2 days in the event of
switch–off or power failure. The clock is programmed via the configuration AT interface

or from the

Server automatically.

2N SmartCOM

®

Wireless M–Bus Interface

This function is available in the

version only, which is equipped

2N SmartCOM PRO

®

with an optional Wireless M-Bus interface. The WM-Bus interface parameters depend
on the module used (radio frequency, e.g.). You can define up to 64 meters from which
the device can collect readings. Having received a WM-Bus message from a meter

defined in the meter table,

saves the message into a circular

2N SmartCOM PRO

®

buffer in the internal memory. The saved data can be retrieved and deleted starting
from the oldest record. When the memory fills up, the oldest data are deleted
automatically to make space to new records. You can define the minimum reading
interval for each meter. Any reading received from a meter before the end of this
interval will not be stored.

The WM-Bus module can work and support encrypted messages in four modes: T1, S1,
C1 and T1+C. In the basic configuration, the terminal does not decrypt messages and
saves them as received. If you enter the correct encryption key and enable decryption,
the received message will be decrypted and saved as a decrypted message. The
encryption keys are not stored in the terminal memory for safety reasons, but written
directly into the module. Therefore, if encryption fails, make sure that the device is
transmitting properly, check the device settings in the terminal and re-enter the
encryption key.