to 'internet.open'. Also, set the server IP address to 90.89.126.3 and the listening port
to 1658. This is the most frequent way of setting.
Thus, send the following configuration SMS:
SC CNF PWD=APNpassword=internet.open IPS=90.89.126.3 PORTS=1658 NPWD=password1
The following reply will come from the terminal after processing:
MODE=1 232LCK=0 APN=internet.open DUSR= DPWD= IPS=90.89.126.3 PORTS=1658
Send the following SMS:Error Buffer
An error buffer is implemented in each terminal to store data on terminal operation
errors. To display the buffer contents use either the terminal (an AT command) or an
SMS. The SMS displays the last 10 errors starting with the most recent one.
SC ERR PWD=<password> [CLR]
CLR – clear the error buffer.
Tip
This command includes one optional parameter –
If you add this
CLR.
string after the password in the command SMS, you will receive an
SMS showing the current buffer contents and all errors will then be
deleted from the terminal memory.
The following reply will come from the terminal after processing:
1:8,10 2:3,10 1:1,0 7:8,10 6:8,7 5:7,40 4:11,848
The following reply will come if there is no error in the error buffer:
NO ERROR
Note
Refer to SC_errors.doc for the meanings of the error codes!
Relay Control
Every terminal is equipped with two relay outputs, which can be SMS controlled. The
configuration SMS must include the password and one of the four programmable
parameters at least.
The programmable parameters include:
R1 or
– define the relay state:
R2