Port 2 (rs 485/m-bus) sc commands – 2N M2M Solution 2N SmartCom - User Manual 1.9.0 User Manual
Page 35

35
0 – none
1 – even
2 – odd
3 – constant 1
4 - constant 0
at^scport1="flowcontrol",1
Enter the command to set the flow control type. Setting options 0-1.
0 - no flow control
1 - hardware flow control
at^scport1="save"
Enter the command to save the changes.
at^scport1="restart"
Enter the command to restart the port.
at^scport1="srestart"
Enter the command to save the changes and restart the interface.
at^scport1?
Enter the command to display the currently set port values.
at^scport1=?
Enter the command to display the port setting options.
^SCPORT1: "BAUDRATE",110-230400
^SCPORT1: "DATA_BITS",5-8
^SCPORT1: "STOP_BITS",1-2
^SCPORT1: "PARITY",0-4
^SCPORT1: "FLOWCONTROL",0-1
^SCPORT1: "SAVE"
^SCPORT1: "RESTART"
^SCPORT1: "SRESTART"
Port 2 (RS 485/M-Bus) SC Commands
These commands are used for setting the RS 485/M-Bus parameters.
at^scport2="baudrate",9600
Enter the command to set the baud rate to 9,600 bps.
at^scport2="baudrate",115200