2N M2M Solution 2N SmartCom - User Manual 1.9.0 User Manual
Page 39

39
Manual calibration setting (maximum values). Setting options: 0 – 960.
at^scadc1="save"
Enter the command to save the changes.
at^scadc1?
Enter the command to display the currently set port values.
at^scadc1=?
Enter the command to display the port setting options.
at^scadc2="get_value"
Enter the command to measure the value of the selected port and send the
measured value.
at^scadc2="adc_value"
Enter the command to make the measurement and return the A/D converter
value.
at^scadc2="calib_min"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scadc2="calib_max"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scadc2="threshold_low",300
Manual calibration setting (minimum values). Setting options: 0 – 960.
at^scadc2="threshold_high",350
Manual calibration setting (maximum values). Setting options: 0 – 960.
at^scadc2="save"
Enter the command to save the changes.
at^scadc2?
Enter the command to display the currently set port values.
at^scadc2=?
Enter the command to display the port setting options.
at^scdin1="get_value"