2N M2M Solution 2N SmartCom - User Manual 1.9.0 User Manual
Page 40

40
Enter the command to detect the logical level on the port and send value 1/0.
at^scdin1="adc_value"
Enter the command to make the measurement and return the A/D converter
value.
at^scdin1="calib_min"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scdin1="calib_max"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scdin1="threshold_low",400
Manual calibration setting (minimum values). Setting options: 0 – 960.
at^scdin1="threshold_high",450
Manual calibration setting (maximum values). Setting options: 0 – 960.
at^scdin1="save"
Enter the command to save the changes.
at^scdin1?
Enter the command to display the currently set port values.
at^scdin1=?
Enter the command to display the port setting options.
at^scdin2="get_value"
Enter the command to detect the logical level on the port and send value 1/0.
at^scdin2="adc_value"
Enter the command to make the measurement and return the A/D converter
value.
at^scdin2="calib_min"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scdin2="calib_max"