Station connections, J28 hydraulic service manifold connector, Station connections 134 – MTS Model FlexTest SE User Manual

Page 134: J28 hydraulic service manifold connector 134, Cable specification

Advertising
background image

Models FlexTest® IIm/GT/SE Controller Hardware

Station Connections

FlexTest GT Controller Connections

134

Station Connections

Each Model 493.74 HSM transition board controls up to two stations. A standard
chassis configuration supports up to four stations. Each station has the following
connections

J28 Hydraulic service manifold (HSM)

J29 Load unit

J43 Interlock

J44 Remote run/stop

J49 Auxiliary power

As a system option, the Model 493.10 Chassis can be configured to support six or
eight stations. See

“Optional Station Configurations”

on page 255.

J28 Hydraulic Service Manifold Connector

Connector J28 HSM controls the pressure of a hydraulic service manifold. The
controller software can configure the connector for solenoid or proportional
control of a 24 volt hydraulic service manifold.

Cable specification

P28 is a 4-contact CPC male connector (AMP Incorporated).

Cable for on/off HSMs–18 AWG/2 conductor with overall foil shield (Carol
C2534 or equivalent) with drain wire connected to pin 3 at the chassis.

Cable for high/low HSMs–18 AWG/4 conductor with overall foil shield
(Carol C2543 or equivalent) with drain wire connected to pin 3 at the
chassis.

1

2

3

4

Low Pressure

DC Common

Shield

High Pressure

To HSM

J28

From Chassis

lo

hi

+24 V

- Proportional

+ Proportional

Solenoid

Solenoid or

Proportional

Valve