Programming and Parameters

3-47

356

Mtr Current Lim

Sets the largest allowable motor stator current. The online maximum value of this
parameter is Par 2 [Motor NP FLA]. The online minimum value is 105% of the current
indicated in Par 488 [Flux Current].

Units:
Default:
Min/Max:

P.U.
1.5000
0.0000/24.0000

✓ ✓ Real

358

Iq Ref Limited

Sets the limit value for the motor torque producing current.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

Real

359

Motor Flux Est

Q-axis motor voltage is divided by the motor frequency while field weakening is active.
This is used to convert the torque command to a motor current (Iqs) command.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

Real

360

Min Flux

Sets the smallest level of flux used to convert Par 303 [Motor Torque Ref] to a current
reference above base speed.

Units:
Default:
Min/Max:

P.U.
0.2500
0.2500/1.0000

✓ ✓ Real

361

Flx LpassFilt BW

Sets the bandwidth of the filter that adjusts the response of the flux estimate used in the
torque to current conversion. Since the field time constant varies between motors, a
better control response may be obtained by adjusting the filter time constant. Normally
this parameter is not changed unless a significant disturbance occurs as the motor enters
field weakening AND Par 360 [Min Flux] is less than 1 per unit.

Units:
Default:
Min/Max:

R/S
12.0000
0.5000/100.0000

✓ ✓ Real

363

Curr Ref TP Sel

Enter or write a value to select current reference data displayed in Par 364 [Curr Ref TP
Data].

Default:
Options:

0
0
1
2
3
4
5
6
7
8
9

“Zero”
“Zero”

10 “Min Lim Stat”

“Iq Sum”

11 “Iq Prescale”

“Iq Lim In”

12 “IqtoIs Stat”

“Iq Lim Out”

13 ‘Flux Status”

“Iq Rate Stat”

14 “Flux LPF Out”

“Limited Flux”

15 “Is Per Unit”

“MtrCrLimStat”

16 “InPos IqLim”

“Lim'dMtrCrLm” 17 “InNeg IqLim”
“Iq Act Limit”

18 “Flx Filt Hld”

“Iq Cal Gain”

364

Curr Ref TP Data

Displays the data selected by Par 363 [Curr Ref TP Sel].

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

Real

365

Encdr0 Loss Cnfg

Enter a value to configure the drive's response to an Encoder 0 Loss exception event.

• 0 “Ignore” - Configures the drive to continue running, as normal, when this event

occurs

• 1 “Alarm” - Configures the drive to continue running and set the appropriate alarm bit

when this event occurs

• 2 “FltCoastStop” - configures the drive to perform a coast stop and set the appropriate

fault bit, in response this event

Default:
Options:

2
0
1
2

“FltCoastStop”
“Ignore”
“Alarm”
“FltCoastStop”

366

Encdr1 Loss Cnfg

Enter a value to configure the drive's response to an Encoder 1 Loss exception event.

• 0 “Ignore” Configures the drive to continue running, as normal, when this event occurs

• 1 “Alarm” - Configures the drive to continue running and set the appropriate alarm bit

when this event occurs

• 2 “FltCoastStop” - Configures the drive to perform a coast stop and set the appropriate

fault bit, in response this event

Default:
Options:

0
0
1
2

“FltCoastStop”
“Ignore”
“Alarm”
“FltCoastStop”

367

FB Opt0 LossCnfg

Enter a value to configure the drive's response to a Feedback Option 0 Loss exception
event.

• 0 “Ignore” Configures the drive to continue running, as normal, when this event occurs

• 1 “Alarm” - Configures the drive to continue running and set the appropriate alarm bit

when this event occurs

• 2 “FltCoastStop” - Configures the drive to perform a coast stop and set the appropriate

fault bit, in response this event

Default:
Options:

0
0
1
2

“FltCoastStop”
“Ignore”
“Alarm”
“FltCoastStop”

368

FB Opt1 LossCnfg

Enter a value to configure the drive's response to a Feedback Option 1 Loss exception
event.

• 0 “Ignore” Configures the drive to continue running, as normal, when this event occurs

• 1 “Alarm” - Configures the drive to continue running and set the appropriate alarm bit

when this event occurs

• 2 “FltCoastStop” - Configures the drive to perform a coast stop and set the appropriate

fault bit, in response this event

Default:
Options:

0
0
1
2

“FltCoastStop”
“Ignore”
“Alarm”
“FltCoastStop”

No.

Name
Description

Values

Li

nkab

le

Read

-Wr

it

e

Da

ta

T

ype