Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual

Page 134

Advertising
background image

3-80

Programming and Parameters

922

Motn TP Select

Selector for diagnostic testpoint relating to Motion functionality.

0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

“ServoAxisCnfg”
“ServoAxisCnfg” 16 ““CST Upper”
“ServoAxisUnwd” 17 “Reserved”
“Marker Dist”

18 “Reserved”

“HomeEvent X”

19 “I/O Rx Seq#”

“Watch Posit”

20 “I/O Rx Msg#”

“Home Posit”

21 “I/O Tx Msg#

“SrvoMRP Ofst” 22 “Syn Rx Seq#”
“SrvoAct Ofst”

23 “Syn RxMsg#”

“PositRegis 1”

24 “Syn Tx Msg#”

“PositRegis 2”

25 “Evt Rx Seq#”

“FdbkAxisCnfg” 26 “Evt Rx Msg#”
“FdbkAxisUnwd” 27 “Evt Rx Tx Msg#”
“FdbkMRP Ofst” 28 “Asy Rx Seq#”
“FdbkAct Ofst”

29 “Asy Rx Msg#”

“TimeEvntStat”

30 “Asy Tx Msg#”

“CST Lower”

31 “Reset Msg#”

923

Motn TP Value

Data for diagnostic testpoint relating to Motion functionality.

Default:
Min/Max:

0
-/+2147483648

DWord

924

Motn RotaryCmmd

Position command input from the Motion Planner to the Servo axis when configured in
rotary mode.

Default:
Min/Max:

0
-/+2147483648

DWord

925

MotnUnwdTurnCmmd

Position unwind turns command input from the Motion Planner to the Servo axis when
configured in rotary mode.

Default:
Min/Max:

0
-/+32768

Word

926

SrvoAxis RotFdbk

Position feedback output to the Motion Planner for the Servo axis when configured in
rotary mode.

Default:
Min/Max:

0
-/+2147483648

DWord

927

SrvoAxisUnwdFdbk

Potion unwind feedback output to the Motion Planner for the Servo axis when configured
in rotary mode.

Default:
Min/Max:

0
-/+32768

Word

928

FdbkAxis RotFdbk

Position feedback output to the Motion Planner for the Feedback Only axis when
configured in rotary mode.

Default:
Min/Max:

0
-/+2147483648

DWord

929

FdbkAxisUnwdFdbk

Position unwind feedback output to the Motion Planner for the Feedback Only axis when
configured in rotary mode.

Default:
Min/Max:

0
-/+32768

Word

930

MotnCnfgErrParam

Indicates a parameter that is not configured properly for a motion connection to be
accepted. Parameter could either have a wrong value or an incorrect link. When bit 0
[Config OK] of Par 907 [Motn Cnct Status} is set, then this parameter contains the
parameter number of an incorrectly configured parameter. If more than one parameter is
incorrectly configured, they are displayed after others are fixed. If there are no
configuration problems relating to Motion, then this parameter contains the value of zero
and bit 0 [Config OK] of Par 907 is cleared.

Default:
Min/Max:

0
0/65535

Word

940

941

+Sft OvrTrvlCnfg

-Sft OvrTrvlCnfg

Synchronization input to the Interpolator has been lost or has become excessively
irregular.

• 0 “Ignore” - configures the drive to continue running, as normal, when this event occurs

• 1 “Alarm” - configures the drive to continue running and set the appropriate alarm bit

when this event occurs

• 2 “FltCoastStop” - configures the drive to perform a coast stop and set the appropriate

fault bit, in response this event.

• 3 “Flt RampStop” - configures the drive to perform a ramp stop and set the appropriate

fault bit, in response this event.

• 4 “FltCurLimStp” - configures the drive to perform a current-limit stop and set the

appropriate fault bit, in response this event.

Default:
Options:

1
0
1
2
3
4

“Alarm”
“Ignore”
“Alarm”
“FltCoastStop”
“Flt RampStop”
“FltCurLimStp”

942

943

+Hrd OvrTrvlCnfg

-Hrd OvrTrvlCnfg

Active signal from a digital input that is configured as a positive hard overtravel input.

• 0 “Ignore” - configures the drive to continue running, as normal, when this event occurs

• 1 “Alarm” - configures the drive to continue running and set the appropriate alarm bit

when this event occurs

• 2 “FltCoastStop” - configures the drive to perform a coast stop and set the appropriate

fault bit, in response this event.

• 3 “Flt RampStop” - configures the drive to perform a ramp stop and set the appropriate

fault bit, in response this event.

• 4 “FltCurLimStp” - configures the drive to perform a current-limit stop and set the

appropriate fault bit, in response this event.

Default:
Options:

1
0
1
2
3
4

“Alarm”
“Ignore”
“Alarm”
“FltCoastStop”
“Flt RampStop”
“FltCurLimStp”

No.

Name
Description

Values

Li

nkab

le

Read

-Wr

it

e

Da

ta

T

ype