Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual

Page 56

Advertising
background image

3-2

Programming and Parameters

No.

Name
Description

Values

Li

nkab

le

Read

-Wr

it

e

Da

ta

T

ype

151

Logic Command

The controller-drive interface (as defined by the Controller Communication Format) sets bits to enable and disable various functions and algorithms. Bits that
are changed here are reflected in Parameter 152 [Applied LogicCmd]. Note: Bits 4 through 9 in Logic Command are NOT recalled from Control EEprom. They
will be cleared upon drive power up or following an EEprom recall operation.

110

Spd/Torq ModeSel

Selects the source for the drive torque reference.

Default:
Options:

1
0
1
2
3

“Speed Reg”
“Zero Torque”

4

“Max Spd/Torq”

“Speed Reg”

5

“Sum Spd/Torq”

“Torque Ref”

6

“AbsMn Spd/Tq”

“Min Spd/Torq”

4

Motor NP RPM

Set to the motor nameplate rated RPM.

Units:
Default:
Min/Max:
Comm Scale:

RPM
Calculated
1/30000
Parameter 4 [Motor NP RPM] = 1.0

✓ 16-bit

Integer

Options

Rese

rv

ed

Rese

rv

ed

P

os

itionEn

bl

Pro

csT

ri

m En

Fr

ic

t C

om

p

In

er

tia

Co

mp

Sys

Iner

t En

Mtr

Ine

rt En

PM Offs

et

En

Dir Sel En

Pwr Diag

En

MC A

tun

e E

n

Time Axis En

Tach

Los

s Rst

Spd S Cr

v En

SpdRa

m

p D

sb

l

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = True
1 = False

No.

Name
Description

No. - Parameter Number

Parameter value cannot be changed until the drive is stopped.

Name - Parameter name as it appears in DriveExecutive software.
Description - Brief description of parameter function.

Values - Define the various operating characteristics of the parameter. There are 3 types of Values.
ENUM

Default:

Lists the value assigned at the factory.

Options:

Displays the selections available.

Bit

Default:

Lists the value assigned at the factory.

Options:

Displays the selections available.

Numeric

Default

Lists the value assigned at the factory.

Min.

Displays lowest possible setting.

Max.

Displays highest possible setting.

Type

Indicates if parameter is linkable, read-write, read-only, and data type (i.e. integer, floating point,
boolean).

Comm
Scale:

Value sent from Controller or Comm Device = Drive Parameter Value x Comm Scale

Advertising