3-76

Programming and Parameters

No.

Name
Description

Values

Li

nk

ab

le

R

ead-

Wri

te

D

ata

T

ype

814

AnlgOut1 Integer

Link this parameter to an integer source parameter and that source will control Analog
Output 1.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

815

Anlg Out1 Real

Link this parameter to a real (floating point) source parameter and that source will control
Analog Output 1.

Default:
Min/Max:

0.0000
-/+2200000000.0000.0000

✓ ✓ Real

816

Anlg Out1 Volts

Displays the voltage reference for Analog Output 1, before the digital to analog
conversion.

Units:
Default:
Min/Max:

Volt
0.0000
-/+10.0000

Real

817

Anlg Out1 Scale

Scales the range of the source parameter to the range of Analog Output 1. Par 814
[AnlgOut1 Integer] or Par 815 [Anlg Out1 Real] is multiplied by this number after the limit
function.

Units:
Default:
Min/Max:

/1v
0.0000
-/+2200000000.0000

v

✓ Real

818

Anlg Out1 Zero

Applies an offset to the scaled value of the Analog Output 1 function. This parameter is
summed with the output of the scaling block. This sum produces Par 816 [Anlg Out1
Volts]. Typically this value corresponds to 0V for Analog Output 1.

Units:
Default:
Min/Max:

Volt
0.0000
-/+20.0000

✓ ✓ Real

819

AnlgOut2 Integer

Link this parameter to an integer source parameter and that source will control Analog
Output 2.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ Real

820

Anlg Out2 Real

Link this parameter to a real (floating point) source parameter and that source will control
Analog Output 2.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

821

Anlg Out2 Volts

Displays the voltage reference for Analog Output 2, before the digital to analog
conversion.

Units:
Default:
Min/Max:

Volt
0.0000
-/+10.0000

Real

822

Anlg Out2 Scale

Scales the range of the source parameter to the range of Analog Output 2. Par 819
[AnlgOut2 Integer] or Par 820 [Anlg Out2 Real] is multiplied by this number after the limit
function.

Units:
Default:
Min/Max:

/1v
0.0000
-/+2200000000.0000

✓ ✓ Real

823

Anlg Out2 Zero

Applies an offset to the scaled value of the Analog Output 2 function. This parameter is
summed with the output of the scaling block. This sum produces Par 821 [Anlg Out2
Volts]. Typically this value corresponds to 0V for Analog Output 2.

Units:
Default:
Min/Max:

Volt
0.0000
-/+20.0000

✓ ✓ Real

824

Local I/O Status

Displays the status of the local I/O.

825

En In Debounce

Sets the value of the debounce filter for the Enable input. The filter requires the input
signal to be stable for the specified time period. Input transitions within the filter time
setting will be ignored.

Units:
Default:
Min/Max:

mSec
8.0000/0.0000
15.5000

✓ ✓ Real

826

DigIn1 Data

Sets the value of Par 828 [DigIn1 User Data], except for the bit controlled by bit 1 [DigIn 1]
of Par 824 [Local I/O Status].

Default:
Min
Max:

00000000000000000000000000000000
00000000000000000000000000000000
11111111111111111111111111111111

✓ ✓ 32-bit

Boolean

827

DigIn1 Bit

Selects the bit, in Par 828 [DigIn1 User Data], which is controlled by bit controlled by bit 1
[DigIn 1] of Par 824 [Local I/O Status].

Default:
Min/Max:

0
-32/31

✓ ✓ 16-bit

Integer

828

DigIn1 User Data

Provides a source of data controlled by bit 1 [DigIn 1] of Par 824 [Local I/O Status].

Link to a Read-Write parameter and enter a value of 13 in Par 838 [DigIn1 Sel] to activate
this function.

Default:
Min:
Max:

00000000000000000000000000000000
00000000000000000000000000000000
11111111111111111111111111111111

32-bit
Boolean

829

DigIn1 Debounce

Sets the value of the debounce filter for Digital Input 1. The filter requires the input signal
to be stable for the specified time period. Input transitions within the filter time setting will
be ignored.

Units:
Default:
Min/Max:

mSec
8.0000
0.0000/15.5000

✓ ✓ Real

830

DigIn2 Data

Sets the value of Par 832 [DigIn2 User Data], except for the bit controlled by bit 2 [DigIn 2]
of Par 824 [Local I/O Status].

Default:
Min:
Max:

00000000000000000000000000000000
00000000000000000000000000000000
11111111111111111111111111111111

✓ ✓ 32-bit

Boolean

831

DigIn2 Bit

Selects the bit, in Par 832 [DigIn2 User Data], which is controlled by bit controlled by bit 2
[DigIn 2] of Par 824 [Local I/O Status].

Default:
Min/Max:

0
-32/31

✓ ✓ 16-bit

Integer

Options

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

VPL Gate Ena

Wa

tc

h D

og

VP TP2 Out

VP TP1 Out

Au

x O

ut

2

Au

x O

ut

1

Out

put

R

ela

y

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Log

ix

Pre

sent

DigI

n 3

DigI

n 2

DigI

n 1

Enab

le

In

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True