Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual

Page 149

Advertising
background image

Programming and Parameters

3-95

1317

User Data Real 03

General purpose parameter available for storage of real data by the operator. This value
will be retained through a power cycle.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

1318

User Data Real 04

General purpose parameter available for storage of real data by the operator. This value
will be retained through a power cycle.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

1319

User Data Real 05

General purpose parameter available for storage of real data by the operator. This value
will be retained through a power cycle.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

1320

User Data Real 06

General purpose parameter available for storage of real data by the operator. This value
will be retained through a power cycle.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

1370

Switch Control

Set bits to control the two software SPDT switches.

• Bit 1 [SW Int 1 On] controls the integer switch. Setting bit 1 moves the value from Par 1371 [SW Int 1 NO] into Par 1373 [SW Int 1 Output]. Resetting this bit moves

the value of Par 1372 [SW Int 1 NC] into Par 1373 [SW Int 1 Output].

• Bit 2 [SW Real 1 On] controls the real switch. Setting bit 2 moves the value from Par 1374 [SW Real 1 NO] into Par 1376 [SW Real 1 Output]. Resetting this bit

moves the value of Par 1375 [SW Real 1 NC] into Par 1376 [SW Real 1 Output].

1371

SW Int 1 NO

The integer switch moves the value of this parameter into Par 1373 [SW Int 1 Output]
when bit 0 [SW Int 1 On] of Par 1370 [Switch Control] is set.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

1372

SW Int 1 NC

The integer switch moves the value of this parameter into Par 1373 [SW Int 1 Output]
when bit 0 [SW Int 1 On] of Par 1370 [Switch Control] is reset.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

1373

SW Int 1 Output

Displays the output of the integer switch. It will reflect the value of either Par 1371 [SW Int
1 NO] or 1372 [SW Int 1 NC].

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

1374

SW Real 1 NO

The real switch moves the value of this parameter into Par 1376 [SW Real 1 Output] when
bit 0 [SW Int 1 On] of Par 1370 [Switch Control] is set.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

1375

SW Real 1 NC

The real switch moves the value of this parameter into Par 1376 [SW Real 1 Output] when
bit 0 [SW Int 1 On] of Par 1370 [Switch Control] is reset.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

1376

SW Real 1 Output

Displays the output of the real switch. It will reflect the value of either Parameter 1374 [SW
Real 1 NO] or 1375 [SW Real 1 NC].

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

No.

Name
Description

Value

Li

nkab

le

Read

-Wr

it

e

Da

ta

T

ype

Options

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

SW Real 1 On

SW In

t 1 On

Re

ser

ved

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True