Programming and Parameters

154

Stop Dwell Time

Sets an adjustable delay time between detecting zero speed and disabling the speed and
torque regulators, when responding to a stop command. For more information, please
see

Stop Dwell Time on page C-5

.

Important:

Consult industry and local codes when setting the value of this
parameter.

Units:
Default:
Min/Max:

Sec
0.0000
0.0000/10.0000l

✓ ✓ Real

155

Logic Status

Displays the status - condition of the drive.

156

Run Inhibit Stat

Indicates which condition is preventing the drive from starting or running.

157

Logic Ctrl State

Indicates which logic control functions are enabled.

No.

Name
Description

Values

Li

nkab

le

Read

-Wr

it

e

Da

ta

T

ype

Options

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Comma

nd Run

Star

t A

ctiv

e

P

osition

Mode

Spe

ed Mode

Tor

que

Mo

de

Res

er

ved

Spd

Co

mm

is

MC Commis

MC En Ac

k

Abo

ve Setpt2

At

Se

tp

t 1

Res

er

ved

At Se

tp

t Spd

At

Z

ero

Sp

d

Ta

ch

L

os

s

Sw

At L

imit

Run

Re

ady

Flas

h Mo

de

Alar

m

Faulte

d

Jo

gging

Dec

elera

ting

Acc

eler

ating

Actua

l Dir

Comma

nd Dir

Run

ning

Ena

bled

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

Bit Name

Current Function

Bit

Name

Current Function

0

Enabled

Drive is controlling motor

14

At Setpt Spd Speed feedback is within limits defined in Par 41

[Limited Spd Ref] and 171 [Set Speed Lim]

1

Running

Run command received & controlling motor

15

Reserved

2

Command
Dir

Commanded direction is forward

16

At Setpt 1

Par 172 [Setpt 1 Data] value is within limits defined
by Par 173 [Setpt1 TripPoint] and 174 [Setpt 1 Limit]

3

Actual Dir

Actual motor direction is forward

17

Above Setpt
2

Par 175 [Setpt 2 Data] value is within limits defined
by Par 176 [Setpt2 TripPoint] and 177 [Setpt 2 Limit]

4

Accelerating Motor is increasing speed

18

MC En Ack

Drive is controlling motor (same as enabled)

5

Decelerating Motor is decreasing speed

19

MC Commis Motor control commissioning in progress

6

Jogging

Jog command received & controlling motor

20

Spd Commis Speed control commissioning in progress

7

Faulted

Exception event that causes a fault has occurred

21

Reserved

8

Alarm

Exception event that causes an alarm has occurred

22

Torque Mode Par 110 [Spd/Torq ModeSel] value is 2, 3, 4, 5 or 6

9

Flash Mode Flash upgrade in progress

23

Speed Mode Par 110 [Spd/Torq ModeSel] value is 1 & position

control is not enabled

10

Run Ready Enable input is high & drive is fault free

24

Position
Mode

Position control active & Par 110 [Spd/Torq
ModeSel] value is not 2, 3, 4, 5 or 6

11

At Limit

Speed, Power, Current or Torque is being limited, refer to
Par 304

25

Start Active

Start command received & controlling motor

12

Tach Loss
SW

Failure is detected in primary speed or position feedback
device & drive has switched to secondary device

26

Command
Run

Run command received

13

At Zero Spd Speed feedback is within limits defined in Par 160

27-31

Reserved

0 = False
1 = True

Options

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

PM Mt

r

Fd

bk

Motin Shtdo

wn

Dig

In Con

fig

Bus PreChrg

Encod

er PPR

Jog

Sta

rt

Flash Upg

rd

Po

w

er

E

E

Po

w

er

L

os

s

SW I L

im

Stp

SW Coa

st Stp

SW Ramp

Stop

No Enab

le

Fa

ul

te

d

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Options

Procs

Tr

im En

Cmd Dir

Upo

l

Lg

x I/

O

Cn

x

Lg

x Run Mode

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

PM Of

fs

et

Rq

Mt

r Di

r Req

Pwr Dia

g

R

eq

MC At

une Req

FT

D Ra

mp E

n

MC En Req

R

T

hr

u Flux

DC Br

ak

e En

Mtr Sim

Mo

de

R

T

hr

u Coas

t

CurrRef En

F

orc

ed Spd

To

rq

Re

f En

Spd

Re

g E

n

SRe

g IntgHld

CurrLim Stop

J Ts

t FulSpd

Iner

t Tst

E

n

Po

si

tio

nE

nb

l

SRe

f SCr

v

En

SRe

f Ramp En

Spd

Re

f En

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Advertising