Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual

Page 84

Advertising
background image

3-30

Programming and Parameters

No.

Name
Description

Values

Li

nk

ab

le

R

ead-

Wri

te

D

ata

T

ype

210

PeakDtct Ctrl In

Sets the configuration of the two peak/level detectors.

• When set (in Set mode), bit 0 [Peak 1 Set] and 4 [Peak 2 Set] are level detectors that causes their output bit to match their preset bit value (Par 214

[PeakDtct1 Preset] and Par 218 [PeakDtct2 Preset], respectively).

• When set (in Hold mode), bit 1 [Peak 1 Hold] and 5 [Peak 2 Hold] are level detectors that cause their output to hold the present min/max.

• When bits 1 and 4 (Set mode) and 2 and 5 (Hold mode) are off, their output bit captures the peak min/max.

• Bits 2 [Peak 1 Sel] and 6 [Peak 2 Sel] determine if the peak/level detectors are positive of negative. If the bit is set the detector detects positive peaks or

levels above the preset. If the bit is not set the detector detects negative peaks (“valleys") or levels below the preset. The output shows the min. or max. peak.

211

Peak Ctrl Status

Status of the peak/level detectors. A peak detector sets its bit when it detects a peak or when its input exceeds its preset - depending on the selected mode.

212

PeakDtct1 In Int

Integer input to the first peak/level detector.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

213

PkDtct1 In Real

Floating point input to the first peak/level detector.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

214

PeakDtct1 Preset

The first peal/level detector (in set or hold modes) compares this value to its input (Par
212 [PeakDtct1 In Int] or 213 [PkDtct1 In Real]) for level detection. When the detector
trips (in set mode) it transfers the value of this parameter to its output (Par 215
[PeakDetect1 Out]).

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

215

PeakDetect1 Out

Output from the first peak/level detector.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

216

PeakDtct2 In Int

Integer input to second peak/level detector.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

217

PkDtct2 In Real

Floating point input to second peak/level detector.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

218

PeakDtct2 Preset

The second detector (in set or hold modes) compares this value to its input (Par 216
[PeakDtct2 In Int] or 217 [PkDtct2 In Real]) for level detection. When the detector trips (in
set mode) it transfers the value of this parameter to its output (Par 219 [PeakDetect2
Out]).

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

219

PeakDetect2 Out

Output from the second peak/level detector.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Real

220

Spd Observer BW

Sets the internal bandwidth for the speed feedback observer. The setting should be as
high a possible, preferably at least 6 times the value of Par 90 [Spd Reg BW]. A setting of
1000 rad/sec is reasonable for most applications. The speed observer is bypassed when
set to zero.

Units:
Default:
Min/Max:

R/S
0.0000
0.0000/1200.0000

✓ ✓ Real

221

Load Estimate

Displays the estimated load torque, which is the side effect of the speed observer and
does not include torque to accelerate or decelerate the motor if the inertia input is correct.
This value is provided for display purposes.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

Real

222

Motor Fdbk Sel

Enter or write a value to select the primary motor speed feedback device.

Default:
Options:

0
0
1
2
3

“Encoder 0”
“Encoder 0”

4

“Motor Sim”

“Encoder 1”

5

“FB Opt Port0”

“Sensorless”

6

“FB Opt Port1”

“Reserved”

223

Mtr Fdbk Alt Sel

Selects the alternate feedback device if the feedback selected from Par 222 [Motor Fdbk
Sel] fails.

Default:
Options:

0
0
1
2
3

“Encoder 0”
“Encoder 0”

4

“Motor Sim”

“Encoder 1”

5

“FB Opt Port0”

“Sensorless”

6

“FB Opt Port1”

“Reserved”

Options

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

Reser

ved

P

eak

2

Se

l

P

eak

2

Ho

ld

P

eak

2

Se

t

Reser

ved

P

eak

1

Se

l

P

eak

1

Ho

ld

P

eak

1

Se

t

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Options

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

P

eak 2 Chng

P

eak 1 Chng

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True