Installation/Wiring
Input/Output
Connection Examples — 3-Wire Control
Required Parameter Changes
High Speed Inputs
12 or 24V DC
Sourcing High Speed Inputs, Used for 3 Wire Control - using
the internal power supply
• Set the value of Parameter 839 [DigIn2 Sel] to a
value of 1 - Normal Stop
• Set the value of Parameter 840 [DigIn3 Sel] to a
value of 2 - Start
• Set Parameter 153 [Control Options] / bit 8
“3WireControl”
Note: +12V and +24V are also available from
TB1 Top 10 & 11.
Sourcing High Speed Inputs, Used for 3 Wire Control - using an
external power supply
Table 1.O TB2 - Row T (Top) Wiring Examples
3 4 5 6
2
1
Start
Stop
7
POWER
COMMON
(RETURN)
EXTERNAL
POWER SUPPLY
3 4 5 6
Start
Stop
7
Advertising