Rockwell Automation 20D PowerFlex 700S Drive Ph I Control, Frames 1...11 User Manual
Page 44

1-30
Installation/Wiring
Table 1.P TB2 - Row B (Bottom) Terminals
Terminal
Signal
Description
Related
Pa
ra
m
et
er
B13
Encoder Signal A
Secondary encoder interface.
5 or 12V DC switch
selectable
(1)
, Nominal
current draw per channel @
12V DC 45 mA, @5V DC 32
mA
Maximum input frequency for
Encoders 0 & 1 is 500 kHz.
(1)
Encoder Input Settings on page 1-32
for necessary dip switch settings.
222, 240,
241, 242,
243, 244,
245, 246,
247, 248
B12
Encoder Signal Not A
B11
Encoder Signal B
B10
Encoder Signal Not B
B9
Encoder Signal Z
B8
Encoder Signal Not Z
B7
Shield
Connection point for encoder
shield.
B6
Unused
B5
Relay Output
Relay contact output.
Rating: 5A @ 24V DC
Resistive, 2A 24V DC
Inductive
824, 841,
842
B4
Relay Output Return
B3
Unused
B2
Power Supply +12V DC (B) (+)
15/2V DC power supply for
secondary encoder interface.
Rating 300 mA
(2)
(3)
(2)
This power supply supports only the secondary encoder interface. Do not use it to power circuits outside of the
drive
(3)
To enable 5V supply, set Jumper J6 (located in the Main Control Board) to positions T2 and T3. Default 12V
supply is set to T1 and T2.
B1
Power Supply +12V DC Return (B) (-)
B1 2
3
4
5
6
7
8