Programming and Parameters

3-25

153

Control Options

Set bits to configure the options for operating the drive.

No.

Name
Description

Values

Li

nkab

le

Read

-Wr

it

e

Da

ta

T

ype

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Tr

q T

ri

m

E

n

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

A

ux Pwr

Sp

ly

A

uto

T

ac

h

Sw

Re

se

rv

ed

Re

se

rv

ed

OL

Cl

sL

pDsb

l

Jog -N

oIn

teg

Iq

De

la

y

Mo

tor Dir

2W

C

oas

tS

to

p

3W

ireCon

tr

ol

S

top

Cn

dt

Tq

St

op

in

T

orq

Jog - NoR

amp

Jog in

Torq

2W

Cu

rr

Li

m

S

tp

S

reg

LP

F 1

S

Ref Filt En

B

ipo

la

r SRef

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

0

0

0

0

0

0

1

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

Bit

Name

Current Function

0

Bipolar SRef

When this bit is enabled a bipolar speed reference is used. In bipolar reference mode,

Par 40

[Selected Spd Ref] indicates both the

speed magnitude and the direction: Positive speed reference values (+) = forward direction and negative speed reference values (–)
= reverse direction. When this bit is disabled a unipolar speed reference is used. In unipolar mode, the speed reference is limited to a
minimum value of zero (0). In this case

Par 40

[Selected Spd Ref] supplies only the speed magnitude. The direction is determined by

Par 153

[Applied LogicCmd] bits 20 [UniPol Fwd] and 21 [UniPol Rev]. The forward/reverse direction button on the HIM is one

possible source for the [Applied Logic Command] direction bits. The following chart explains the effect that the direction button on the
HIM has based on the condition of the “Bipolar SRef” bit:
Bipolar

Reference Controlled By HIM? HIM Direction Button

Enabled

Yes

Changes the motor direction due to a HIM supplied (+) or (-) command signal

Enabled

No

Has no effect on motor direction. Direction determined by sign of

Par 40

[Selected Spd

Ref].

Disabled

Yes

Changes the motor direction due to a HIM supplied Forward or Reverse Logic
Command bit.

Disabled

No

Changes the motor direction due to a HIM supplied Forward or Reverse Logic
Command bit.

In either Bipolar or Unipolar mode, the selected direction can be determined from the sign of

Par 41

[Limited Spd Ref]. Positive

values indicate forward rotation and negative values indicate reverse rotation.

1

SRef Filt En

Enables Speed Reference Lead Lag Filter-reset disables

2

Sreg LPF 1

Setting this bit will enable the speed regulator filter as a single order low pass filter

4

Jog in Torq

Overrides Par 110 [Spd/Torq ModeSel] setting when jog command received

5

Jog-NoRamp

Bypasses the Speed Reference Ramp and S-Curve

6

Stop in Torq

Overrides Par 110 [Spd/Torq ModeSel] setting when stopping

8

3WireControl

Configures for 3-wire control

11

Iq Delay

Enables Torque Current Delay option

12

Jog-NoInteg

Configures speed regulator’s integrator to hold when jogging

17

Aux Pwr Sply

Enables use of Aux. Power Supply. When set to 1, Main Control Board examines internal 12V DC power to see when energized.
When set to 0, examines voltage of DC Bus. This bit enables Main Control Board and DriveLogix Controller to remain energized
when 3-Ø voltage is de-energized.

0 = False
1 = True