Programming and Parameters

3-65

645

Real Out06

Displays output word 06 of the controller communication format in floating point format.
Paired with Par 644 [Integer Out06], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

646

Integer Out07

Displays output word 07 of the controller communication format in integer format. Paired
with Par 647 [Real Out07], which displays the same data in floating point format.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

647

Real Out07

Displays output word 07 of the controller communication format in floating point format.
Paired with Par 646 [Integer Out07], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

648

Integer Out08

Displays output word 08 of the controller communication format in integer format. Paired
with Par 649 [Real Out08], which displays the same data in floating point format.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

649

Real Out08

Displays output word 08 of the controller communication format in floating point format.
Paired with Par 648 [Integer Out08], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

650

Integer Out09

Displays output word 09 of the controller communication format in integer format. Paired
with Par 651 [Real Out09], which displays the same data in floating point format.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

651

Real Out09

Displays output word 09 of the controller communication format in floating point format.
Paired with Par 650 [Integer Out09], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

652

Integer Out10

Displays output word 10 of the controller communication format in integer format. Paired
with Par 653 [Real Out10], which displays the same data in floating point format.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

653

Real Out10

Displays output word 10 of the controller communication format in floating point format.
Paired with Par 652 [Integer Out10], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

654

Integer Out11

Displays output word 11 of the controller communication format in integer format. Paired
with Par 655 [Real Out11], which displays the same data in floating point format.

Default:
Min/Max:
Comm Scale:

0
-/+2147483648
x16

✓ ✓ 32-bit

Integer

655

Real Out11

Displays output word 11 of the controller communication format in floating point format.
Paired with Par 654 [Integer Out11], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

656

Integer Out12

Displays output word 12 of the controller communication format in integer format. Paired
with Par 657 [Real Out12], which displays the same data in floating point format.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

657

Real Out12

Displays output word 12 of the controller communication format in floating point format.
Paired with Par 656 [Integer Out12], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

658

Integer Out13

Displays output word 13 of the controller communication format in integer format. Paired
with Par 659 [Real Out13], which displays the same data in floating point format.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

659

Real Out13

Displays output word 13 of the controller communication format in floating point format.
Paired with Par 658 [Integer Out13], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

660

Integer Out14

Displays output word 14 of the controller communication format in integer format. Paired
with Par 661 [Real Out14], which displays the same data in floating point format.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

661

Real Out14

Displays output word 14 of the controller communication format in floating point format.
Paired with Par 660 [Integer Out14], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

662

Integer Out15

Displays output word 15 of the controller communication format in integer format. Paired
with Par 663 [Real Out15], which displays the same data in floating point format.

Default:
Min/Max:

0
-/+2147483648

✓ ✓ 32-bit

Integer

663

Real Out15

Displays output word 15 of the controller communication format in floating point format.
Paired with Par 662 [Integer Out15], which displays the same data in integer format.

Default:
Min/Max:

0.0000
-/+2200000000.0000

✓ ✓ Real

664

Lgx Comm Format

Indicates the Controller to Drive communication format. 16-Velocity Control, 0-Custom
Format, 16-Position Control.

Default:
Options:

0
0
16
17

“Not Used”
“Not Used”

18 “UserDefined”

“Velocity”

19 “Motion”

“Position”

32 CustmUserDef

No.

Name
Description

Values

Li

nkab

le

Read

-Wr

it

e

Da

ta

T

ype

Advertising