A-3

Control

Method
Induction Motor:
Brushless Motor:

Sine coded PWM with programmable carrier frequency, Indirect
Self-Organized, Field-Oriented Control, Current-regulated.
Ratings apply to all drives. Refer to the PowerFlex® 700S -
Phase I Control Reference Manual, publication PFLEX-RM002,
for derating guidelines. The drive can be supplied as 6 pulse or
12 pulse in a configured package.

Sine coded PWM with programmable carrier frequency, Indirect
Self-Organized, Field-Oriented Control, Current-regulated.
Ratings apply to all drives. Refer to the PowerFlex® 700S -
Phase I Control Reference Manual, publication PFLEX-RM002,
for derating guidelines. The drive can be supplied as 6 pulse or
12 pulse in a configured package.

Carrier Frequency

Drive rating: 4 kHz
Settings: 2, 4, 8, 10 kHz

Drive rating: 2 kHz
Settings: 2, 4, 8, 10 kHz

e

g

a

tl

o

v

r

o

t

o

m

d

e

t

a

r

o

t

0

e

g

a

tl

o

v

r

o

t

o

m

d

e

t

a

r

o

t

0

:

e

g

n

a

R

e

g

a

tl

o

V

t

u

p

t

u

O

z

H

0

2

3

0

z

H

0

2

3

0

:

e

g

n

a

R

y

c

n

e

u

q

e

r

F

t

u

p

t

u

O
Speed Control

Speed regulation - without feedback

0.1% of base speed across 120:1 speed range
120:1 operating range

50 rad/sec bandwidth

Speed regulation - without feedback

0.1% of base speed across 120:1 speed range
120:1 operating range

50 rad/sec bandwidth

Speed regulation - with feedback

0.001% of base speed across 120:1 speed range
1000:1 operating range
300 rad/sec bandwidth

Speed regulation - with feedback

0.001% of base speed across 120:1 speed range
1000:1 operating range
300 rad/sec bandwidth

Torque Regulation

Torque Regulation - without feedback

+/-10%, 600 rad/sec bandwidth

Torque Regulation - without feedback

+/-10%, 600 rad/sec bandwidth

Torque Regulation - with feedback

+/-2%, 2500 rad/sec bandwidth

Torque Regulation - with feedback

+/-5%, 2500 rad/sec bandwidth

Selectable Motor Control:

Field Oriented Control with and without a feedback device and
permanent magnet motor control

Field Oriented Control with and without a feedback device and
permanent magnet motor control

Stop Modes:

Multiple programmable stop modes including – Ramp, Coast
and Current Limit

Multiple programmable stop modes including – Ramp, Coast
and Current Limit

Accel/Decel

Independently programmable accel and decel times adjustable
from 0 to 6553.5 in 0.1 second increments.

Independently programmable accel and decel times adjustable
from 0 to 6553.5 in 0.1 second increments.

s

d

n

o

c

e

s

0

.

4

o

t

5

.

0

m

o

r

f

e

l

b

a

t

s

u

j

d

A

s

d

n

o

c

e

s

0

.

4

o

t

5

.

0

m

o

r

f

e

l

b

a

t

s

u

j

d

A

e

m

i

T

e

v

r

u

C

-

S
Intermittent Overload:

110% Overload capability for up to 1 minute
150% Overload capability for up to 3 seconds

110% Overload capability for up to 1 minute
150% Overload capability for up to 3 seconds

Current Limit Capability:

Independent Motoring and Regenerative Power Limits
programmable to 800% of rated output current

Independent Motoring and Regenerative Power Limits
programmable to 800% of rated output current

Electronic Motor Overload
Protection

Provides class 10 motor overload protection according to NEC
article 430 and motor over-temperature protection according to
NEC article 430.126 (A) (2). UL 508C File E59272.

Category

Specification

Frames 1-6 (690V Drive frames 5 & 6 only)

Frames 9 & up

Provides class 10 motor overload protection according to NEC
article 430 and motor over-temperature protection according to
NEC article 430.126 (A) (2). UL 508C File E59272.