3-28

Programming and Parameters

167

Motor Ctrl Ackn

Displays the Motor Control Processor's acknowledgment to the Velocity Processor for the Motor Control Command bits.

169

SrLss ZeroSpdLim

Functionally equivalent to Par 160 [Zero Speed Lim], but is used exclusively in
Sensorless speed mode. The value is automatically set from Par 3 [Motor NP Hertz], Par
4 [Motor NP RPM] or Par 7 [Motor Poles]. The automatic setting corresponds to the rated
slip speed of the motor (synchronous speed - nameplate speed). The value can be
manually set.

Units:
Default:
Min/Max:

RPM
49.9975
0.0000/875.0000

✓ Real

171

Set Speed Lim

Creates a tolerance - hysteresis band around the value in Par 41 [Limited Spd Ref] for
comparison to average speed feedback. The comparison controls bit 14 [At Setpt Spd] of
Par 155 [Logic Status]. In general bit 14 [At Setpt Spd] turns on when the feedback is
within the tolerance of the reference. Technically - Turn-on level for rising feedback = Par
41 [Limited Spd Ref] - Limit. Turn-off level for rising feedback = {Limited Spd Ref} +
2(Limit). Turn-on level for falling feedback = [Limited Spd Ref} + Limit. Turn-off level for
falling feedback = [Limited Spd Ref] - 2(Limit).

Units:
Default:
Min/Max:
Comm Scale:

RPM
17.6400
0.0000/882.0000
Par 4 [Motor NP RPM] = 1.0

✓ ✓ Real

172

Setpt 1 Data

Provides data for comparison to Par 173 [Setpt1 TripPoint], driving bit 16 [At Setpt 1] of
Par 155 [Logic Status]. For more information, please see

Setpt 1 Data on page C-6

.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

✓ ✓ Real

173

Setpt1 TripPoint

Provides the midpoint for operation of bit 16 [At Setpt 1] of Par 155 [Logic Status].

Units:
Default:
Min/Max:

P.U.
0.1000
-/+8.0000

✓ ✓ Real

174

Setpt 1 Limit

Creates a tolerance - hysteresis band around the value in Par 173 [Setpt1 TripPoint].
Turn-on level for ascending data = [Setpt1 TripPoint] - [Setpt 1 Limit]. Turn-off level for
ascending data = [Setpt1 TripPoint] + 2(Limit). Turn-on level for descending data =
[Setpt1 TripPoint] + Limit. Turn-off level for descending data = [Setpt1 TripPoint] - 2(Limit).

Units:
Default:
Min/Max::

P.U.
0.0100
0.0000/0.5000

✓ ✓ Real

175

Setpt 2 Data

Provides data for comparison to Par 177 [Setpt2 Limit], driving bit 17 [Above Setpt 2] of
Par 155 [Logic Status]. For more information, please see

Setpt 2 Data on page C-6

.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

✓ ✓ Real

176

Setpt2 TripPoint

Provides the midpoint for operation of bit 16 [At Setpt 1] of Par 155 [Logic Status].

Units:
Default:
Min/Max:

P.U.
0.2000
-/+8.0000

✓ ✓ Real

177

Setpt 2 Limit

Creates a tolerance - hysteresis band around the value in Par 176 [Setpt2 TripPoint]. For
positive setpoints: Turn-on level = [Setpt2 TripPoint], Turn-off level = [Setpt2 TripPoint] -
Limit. For negative setpoints: Turn-on level = [Setpt2 TripPoint], Turn-off level = [Setpt2
TripPoint] + Limit.

Units:
Default:
Min/Max:

P.U.
0.0100
0.0000/0.5000

✓ ✓ Real

180

PI Output

The final output of the Process Control regulator. A value of 1 can represent either base
motor speed, motor rated torque, or 100% for some external function.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

Real

181

PI Reference

The reference input for the process control regulator. A value of 1 can represent either
base motor speed, motor rated torque, or 100% for some external function.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

✓ ✓ Real

182

PI Feedback

The feedback input for the process control regulator. A value of 1 can represent either
base motor speed, motor rated torque, or 100% for some external function.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

✓ ✓ Real

183

PI Command

Set bits to configure the process control regulator - enable or disable the regulator, enable or disable the time function generator and limit generator.

184

PI Lpass Filt BW

Sets the bandwidth of a single pole filter applied to the error input of the Process Control
regulator. The input to the filter is the difference between Par 181 [PI Reference] and Par
182 [PI Feedback]. The output of this filter is used as the input to the process control
regulator.

Units:
Default:
Min/Max:

R/S
0.0000
0.0000/500.0000

✓ ✓ Real

185

PI Preload

Presets the integrator of the Process Control regulator.

Units:
Default:
Min/Max:

P.U.
0.0000
-/+8.0000

✓ ✓ Real

No.

Name
Description

Values

Li

nkab

le

Read

-Wr

it

e

Da

ta

T

ype

Options

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Fault

Re

set

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Re

ser

ved

Po

w

er

D

ia

g

Pr

ec

har

ge

To

rq

ue Run

Fl

ux

Ru

n

CP

Ena

ble

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Options

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Res

er

ved

Time Lim

En

Enab

le

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Advertising