Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual

Page 102

Advertising
background image

6–12

Publication 1336 FORCE–5.13 –– September, 1998

300

Adapter ID

[Adapter ID]

Adapter ID displays the identifier for the PLC
Communications Adapter Board.

Parameter Number

300

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

1

Minimum Value

1

Maximum Value

1

File – Group

Diagnostics – Info

301

Adapter Version

[Adapter Version]

Adapter Version displays the current firmware
version of the PLC Communications Adapter Board.

Parameter Number

301

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

2.XX

Minimum Value

0.00

Maximum Value

9.99

File – Group

Diagnostics – Info

302

SCANport Communications Retries

[SP Comm Retries]

SP Comm Retries counts the number of
communication retries for all entries in the SCANport
scan list.

Parameter Number

302

Parameter Type

Read, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

65535

File – Group

Diagnostics – Info

303

Channel A DIP Switch

[ChA DIP Switch]

ChA DIP Switch displays the current DIP switch
settings for Channel A of the PLC Communications
Adapter Board. The two groups of numbers on the
left represent block U2, and the two groups on the
right represent block U3.

Parameter Number

303

Parameter Type

Read Only, Source

Display Units / Drive Units

Bits

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

File – Group

Diagnostics – Info

304

Channel B DIP Switch

[ChB DIP Switch]

ChB DIP Switch displays the current DIP switch
settings for Channel B of the PLC Communications
Adapter Board. The two groups of numbers on the
left represent block U4, and the two groups on the
right represent block U5.

Parameter Number

304

Parameter Type

Read Only, Source

Display Units / Drive Units

Bits

Factory Default

0000 0000 0000 0000

Minimum Value

0000 0000 0000 0000

Maximum Value

1111 1111 1111 1111

File – Group

Diagnostics – Info

305

Channel A LED State

[ChA LED State]

ChA LED State displays the current LED state for
channel A. The LED states correspond to LEDs D8,
D10, and D12 on the PLC Communications Adapter
Board.

Parameter Number

305

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

5

File – Group

Diagnostics – Info

Enums

0 = Off

1 = Red

2 = Green

3 = Yellow

4 = Flash Green

5 = Flash Red

Advertising