6–28

Publication 1336 FORCE–5.13 –– September, 1998

370

Direction Owner

[Dir Owner]

Dir Owner displays which port currently has
exclusive control of direction changes.

Parameter Number

370

Parameter Type

Read Only, Source

Display Units / Drive Units

Bits

Factory Default

0

Minimum Value

0

Maximum Value

0FE Hex

File – Group Communications I/O – SCANport Owners

Enums

Bit 1 = Port 1

Bit 2 = Port 2

Bit 3 = Port 3

Bit 4 = Port 4

Bit 5 = Port 5

Bit 6 = Channel A Bit 7 = Channel B

371

Start Owner

[Start Owner]

Start Owner displays which ports are presently
issuing a valid Start command.

Parameter Number

371

Parameter Type

Read Only, Source

Display Units / Drive Units

Bits

Factory Default

0

Minimum Value

0

Maximum Value

0FE Hex

File – Group Communications I/O – SCANport Owners

Enums

Bit 1 = Port 1

Bit 2 = Port 2

Bit 3 = Port 3

Bit 4 = Port 4

Bit 5 = Port 5

Bit 6 = Channel A Bit 7 = Channel B

372

Jog1 Owner

[Jog1 Owner]

Jog1 Owner displays which ports are presently
issuing a valid Jog1 command.

Parameter Number

372

Parameter Type

Read Only, Source

Display Units / Drive Units

Bits

Factory Default

0

Minimum Value

0

Maximum Value

0FE Hex

File – Group Communications I/O – SCANport Owners

Enums

Bit 1 = Port 1

Bit 2 = Port 2

Bit 3 = Port 3

Bit 4 = Port 4

Bit 5 = Port 5

Bit 6 = Channel A Bit 7 = Channel B

373

Jog2 Owner

[Jog2 Owner]

Jog2 Owner displays which ports are presently
issuing a valid Jog2 command.

Parameter Number

373

Parameter Type

Read Only, Source

Display Units / Drive Units

Bits

Factory Default

0

Minimum Value

0

Maximum Value

0FE Hex

File – Group Communications I/O – SCANport Owners

Enums

Bit 1 = Port 1

Bit 2 = Port 2

Bit 3 = Port 3

Bit 4 = Port 4

Bit 5 = Port 5

Bit 6 = Channel A Bit 7 = Channel B

374

Set Reference Owner

[Set Ref Owner]

Set Ref Owner displays which port currently has
exclusive control in selecting the command
frequency source.

Parameter Number

374

Parameter Type

Read Only, Source

Display Units / Drive Units

Bits

Factory Default

0

Minimum Value

0

Maximum Value

0FE Hex

File – Group Communications I/O – SCANport Owners

Enums

Bit 1 = Port 1

Bit 2 = Port 2

Bit 3 = Port 3

Bit 4 = Port 4

Bit 5 = Port 5

Bit 6 = Channel A Bit 7 = Channel B