Setting your protocol, Setting your baud rate – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual

Page 30

Advertising
background image

2–2

Publication 1336 FORCE–5.13 –– September, 1998

Setting Your Protocol

Use the following chart to set switches 1 and 2 on either U2 or U4 to
specify your protocol.

If you are using:

Then set SW1

to:

And SW2 to:

RIO without block transfer

Off

Off

RIO with block transfer

Off

On

DH+

On

Off

RIO scanner mode

On

On

Setting Your Baud Rate

Use the following chart to set switches 3 and 4 on either U2 or U4 to
specify the baud rate that you want to use.

If you want to

communicate at:

Then set

SW3 to:

And SW4 to:

57.6K

Off

Off

115.2K

Off

On

230.4K

On

Off/On

Once you have set the protocol and baud rate DIP switches, you
should go to the section appropriate to your protocol:

If you selected this protocol:

Go to this page:

RIO with or without block transfer

Page 2–3

DH+

Page 2–8

RIO scanner mode

Page 2–6

ON =

OFF =

U2 or U4

Switches 1 and 2

1

2

3

4

5

6

7

8

0

N

0N C

HA

NN

EL A

HIG

H

U2

1

2

3

4

5

6

7

8

0

N

0N C

HA

NN

EL B

HIG

H

U4

RIO without
Block Transfer

RIO with
Block Transfer

DH+
RIO Scanner

SW1

Off

Off

On

On

SW2

Off

On

Off

On

ON =

OFF =

U2 or U4

Switches 3 and 4

1

2

3

4

5

6

7

8

0

N

0N C

HA

NN

EL A

HIG

H

U2

1

2

3

4

5

6

7

8

0

N

0N C

HA

NN

EL B

HIG

H

U4

Baud Rate

57.6K
115.2K
230.4K
230.4K

SW3

Off
Off
On

On

SW4

Off
On
Off

On

Advertising