Example
A Continuous Parameter Link Read is requested for nine parameter
links (word N10:2) beginning with parameter 359. The block
transfer response returns the source parameters that are linked to
parameters 359 through 367. In this example:
•
Parameter 359 is linked to parameter 56.
•
Parameter 360 is linked to parameter 143.
•
Parameter 367 is linked to parameter 380.
•
Parameters 361 through 366 are not linked.
1
0
N10:0
2
3
4
5
6
7
8
9
N10:90
BTW
Data File
BTR
Data File
Data Format
9
359
9
359
4
0
4
4
56
360
59
361
81
362
N10:100
168
364
80
363
167
365
134
366
26
367
N10:110
330
Continuous Parameter Link Read