Trend file – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual
Page 204

7–58
Publication 1336 FORCE–5.13 –– September, 1998
The Trend Command function allows you to send a disable trend,
enable trend, or force trigger command to the drive for a specific
trend operation.
PLC Block Transfer Instruction Data
BTW instruction length:
4 words
BTR instruction length:
3 words
Header
Word 1
Header
Word 1
Header
Word 2
Header
Word 2
Header
Word 3
Trend Number
Message Structure
Data
Word 3
Trend Number
PLC Decimal Value
–28672
PLC Decimal Value
4096 –– Message OK
–28672 –– Message Error
Message Length
4
Message Length
3
PLC Request –– Block Transfer Write
Drive Response –– Block Transfer Read
Data
Word 4
Command
Message Operation
You can use the trend command to send one of the following
commands to the drive: disable trend, enable trend, or force trigger.
To send a Trend Command function, you need to specify both the
trend number and the command number.
The following are the valid trend numbers:
This number:
Specifies that the command is to be sent for:
4096
Trend 1
8192
Trend 2
12228
Trend 3
16384
Trend 4
The following are the valid command numbers:
This number:
Sends a command to:
0
Disable the specified trend.
1
Enable the specified trend.
2
Force a trigger for the specified trend.
Trend File
Trend Command