Data Output C2

[Data Out C2]

Data Out C2 contains the sixth image word from the
SCANport input image table.

Parameter Number

348

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – SCANport I/O

349

Data Output D1

[Data Out D1]

Data Out D1 contains the seventh image word from
the SCANport input image table.

Parameter Number

349

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – SCANport I/O

350

Data Output D2

[Data Out D2]

Data Out D2 contains the eighth image word from
the SCANport input image table.

Parameter Number

350

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – SCANport I/O

351

Channel A Remote I/O Output 0

[ChA RIOA Out 0]

–– adapter mode

[ChA/B RIOA Out0]

––

adapter mode with redundancy

[ChA RIOS Out 0]

–– scanner mode

ChA RIOx Out 0 contains the first word or data
group to the PLC controller input image table. The
data is transferred to the PLC controller every rack
scan. The PLC Communications Adapter Board can
provide this value directly. Other drive functions can
provide this value through a configuration link.

Parameter Number

351➀

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

None

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Channel A

➀ This parameter is not available if you set up channel A for DH+. Availability also
depends on the selected rack size.
NOTE:If Channel A (B) is configured as RIOA w/Block transfer, this parameter is
defined as a source parameter to prevent accidental linking and unpredictable Block
Transfer behavior.

Note: All eight words are displayed regardless of the rack size. Only the number of words corresponding to the rack size and protocol
(with or without block transfer) are functional.

352

Channel A Remote I/O Output 1

[ChA RIOA Out 1]

–– adapter mode

[ChA/B RIOA Out1]

–– adapter mode with redundancy

[ChA RIOS Out 1]

–– scanner mode

ChA RIOx Out 1 contains the second word or data
group to the PLC controller input image table. The
data is transferred to the PLC controller every rack
scan. The PLC Communications Adapter Board can
provide this value directly. Other drive functions can
provide this value through a configuration link.

Parameter Number

352➀

Parameter Type

Read/Write, Sink

Display Units / Drive Units

None

Factory Default

None

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – Channel A

➀ This parameter is not available if you set up channel A for DH+. Availability also
depends on the selected rack size.

Note: All eight words are displayed regardless of the rack size. Only the number of words corresponding to the rack size and protocol
(with or without block transfer) are functional.