Parameter read, Plc block transfer instruction data, Parameter read full – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual

Page 156

Advertising
background image

7–10

Publication 1336 FORCE–5.13 –– September, 1998

The Parameter Read Full function provides the requesting remote
I/O source with all known attributes for the parameters requested.
This information includes the parameter’s current value; descriptor;
multiply and divide value; base value; offset value; text string; file,
group, and element reference; minimum value; maximum value;
default value; and unit text string.

PLC Block Transfer Instruction Data

BTW instruction length:

3 words

BTR instruction length:

23 words

Message Length

3

Header

Word 1

Header

Word 1

PLC Decimal Value

768

Header

Word 2

Data

Word 3

PLC Decimal Value

768 –– Message OK

Header

Word 2

Data

Word 3

-32000 –– Message Error

Parameter Number

Parameter Number

Parameter Value or

Status Word

Descriptor

Multiply Value

Divide Value

Base Value

Offset Value

Parameter Text

Character 2

Character 1

Parameter Text

Character 4

Character 3

Parameter Text

Character 6

Character 5

Parameter Text

Character 8

Character 7

Parameter Text

Character 10

Character 9

Message Structure

Data

Word 4

Data

Word 5

Data

Word 6

Data

Word 7

Data

Word 8

Data

Word 9

Data

Word 10

Data

Word 11

Data

Word 12

Data

Word 13

Data

Word 14

0

PLC Request –– Block Transfer Write

Drive Response –– Block Transfer Read

Parameter Read

Parameter Read Full