4–7
Publication 1336 FORCE–5.13 –– September, 1998
MESSAGE INSTRUCTION DATA MONITOR FOR CONTROL BLOCK N7:0
Rung 2:2
This rung will write parameters 117-123 when bit B3/1 is toggled from zero to one. The parameter values to be sent to the drive are stored in
N30:0-7.
(EN)
(DN)
(ER)
1
Enable Message Write
from Drive 1
B3
Drive 1
Parameter Write
MSG
SEND/REC MESSAGE
Control Block N7:20
Rung 2:3
No More Files
End of File
Communication Command:
PLC-5 TYPED WRITE
PLC-5 Data Table Address:
N30:0
Ignore if timed-out:
0 TO
Size in Elements:
7
to be retried:
0 NR
Local/Remote:
LOCAL
awaiting execution:
0 EW
Remote Station:
N/A
continuous:
0 CO
Link ID:
N/A
error:
0 ER
Remote Link Type:
N/A
message done:
0 DN
Local Node Address:
11
message transmitting:
0 ST
Destination Data Table Address:
N10:117
message enabled:
0 EN
control bit addr: N7:20/15
ERROR CODE:
0 (DEC)
BLOCK SIZE = 10 WORDS
Press a function key to change a value.
>[
Rem Prog Forces: None
Data: Formatted
5/10 File Temp
Size in
Toggle
Elements
Bit