Example, Scattered parameter link read – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual
Page 179

7–33
Publication 1336 FORCE–5.13 –– September, 1998
The corresponding source parameters are returned through the BTR
response.
If an error has occurred in reading any of the links:
•
Word 2 of the BTR returns a value of -32763.
•
Bit 15 of the BTR word for the number of that link is set, making
the value negative.
Example
In this example, a Scattered Parameter Link Read of four links was
requested through the BTW. Sink parameters 119 through 367 and
401 were defined as the desired links to be read. The BTR returned
the corresponding source parameter values in the words reserved for
this information. If an error had occurred for a specific link, the
value returned would be negative.
1
0
2
3
4
5
6
7
8
9
BTW
Data File
Data Format
N10:10
4
119
5
0
368
0
367
0
401
12
N10:20
0
BTW
Data File
N10:90
4
119
5
0
368
331
367
330
401
Sink
Source
Sink
Source
0
N10:100
0
Scattered Parameter Link Read
(continued)