The Trigger Time function allows you to read the trigger time for the
specified trend file from the drive.

PLC Block Transfer Instruction Data

BTW instruction length:

3 words

BTR instruction length:

7 words

Header

Word 1

Header

Word 1

Header

Word 2

Header

Word 2

Header

Word 3

Trend Number

Message Structure

Header

Word 3

Trend Number

PLC Decimal Value

4099

PLC Decimal Value

4099 –– Message OK

–28669 –– Message Error

Message Length

3

Message Length

7

PLC Request –– Block Transfer Write

Drive Response –– Block Transfer Read

Clock Time

Seconds

10ths of MS

Clock Time

Hour

Minute

Clock Time

Date

Day

Clock Time

Year

Month

Data

Word 4

Data

Word 5

Data

Word 6

Data

Word 7

Message Operation

You can use the Trigger Time function to read the trigger time for the
specified trend file from the drive.

The following are the valid trend numbers:

This

number:

Specifies that the command is to be sent for:

4096

Trend 1

8192

Trend 2

12228

Trend 3

16384

Trend 4

Trend File

Trigger Time