Trend file, Plc block transfer instruction data, Message operation – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual
Page 214: Trigger time

7–68
Publication 1336 FORCE–5.13 –– September, 1998
The Trigger Time function allows you to read the trigger time for the
specified trend file from the drive.
PLC Block Transfer Instruction Data
BTW instruction length:
3 words
BTR instruction length:
7 words
Header
Word 1
Header
Word 1
Header
Word 2
Header
Word 2
Header
Word 3
Trend Number
Message Structure
Header
Word 3
Trend Number
PLC Decimal Value
4099
PLC Decimal Value
4099 –– Message OK
–28669 –– Message Error
Message Length
3
Message Length
7
PLC Request –– Block Transfer Write
Drive Response –– Block Transfer Read
Clock Time
Seconds
10ths of MS
Clock Time
Hour
Minute
Clock Time
Date
Day
Clock Time
Year
Month
Data
Word 4
Data
Word 5
Data
Word 6
Data
Word 7
Message Operation
You can use the Trigger Time function to read the trigger time for the
specified trend file from the drive.
The following are the valid trend numbers:
This
number:
Specifies that the command is to be sent for:
4096
Trend 1
8192
Trend 2
12228
Trend 3
16384
Trend 4
Trend File
Trigger Time