The Scattered Parameter Value Read function reads a scattered list of
parameters with each parameter you define. You must also define
the number of parameters to be read.
PLC Block Transfer Instruction Data
BTW instruction length:
5-63 words
BTR instruction length:
5-63 words
Message Length
5-63
Header
Word 1
Header
Word 1
PLC Decimal Value
3
PLC Decimal Value
3 –– Message OK
-32765 –– Message Error
Number of Parameter
Values to Read
Parameter Number
1
Number of Parameter
Values to Read
Parameter
Number 1
Parameter Number
2
0
Parameter Number
3
0
0
•
•
•
•
Data
Word 62
Parameter Number
30
0
Data
Word 63
Bit 15
Parameter Value or
Status Word 1
Parameter
Number 2
Bit 15
Parameter Value or
Status Word 2
Parameter
Number 3
Bit 15
Parameter Value or
Status Word 3
•
•
•
•
Data
Word 62
Data
Word 63
Parameter
Number 30
Bit 15
Parameter Value or
Status Word 30
Message Structure
Header
Word 2
Data
Word 3
Data
Word 4
Data
Word 5
Data
Word 6
Data
Word 7
Data
Word 8
Data
Word 9
Header
Word 2
Data
Word 3
Data
Word 4
Data
Word 5
Data
Word 6
Data
Word 7
Data
Word 8
Data
Word 9
0
PLC Request –– Block Transfer Write
Drive Response –– Block Transfer Read
Parameter Read
Scattered Parameter Value Read