7–25

Publication 1336 FORCE–5.13 –– September, 1998

The Warning Queue Read Full function reads the contents of the
specified warning queue entry number. A message is returned that
includes the warning text and warning code associated with the
specified warning queue entry and the time stamp associated with the
fault.

PLC Block Transfer Instruction Data

BTW instruction length:

3 words

BTR instruction length:

16 words

Header

Word 1

Header

Word 1

PLC Decimal Value

2048

Header

Word 2

Data

Word 3

Header

Word 2

Header

Word 3

PLC Decimal Value

2048 –– Message OK

-30720 –– Message Error

Message Structure

Message Length

3

0

Warning Queue Entry

Number

Warning Queue Entry

Number

Data

Word 4

Warning Text

Character 2

Character 1

Data

Word 5

Warning Text

Character 4

Character 3

Data

Word 6

Warning Text

Character 6

Character 5

Data

Word 7

Warning Text

Character 8

Character 7

Data

Word 8

Warning Text

Character 10

Character 9

Data

Word 9

Warning Text

Characcter 12

Character 11

Data

Word 10

Warning Text

Character 14

Character 13

Data

Word 11

Warning Text

Character 16

Character 15

Warning Code Value

Data

Word 12

PLC Request –– Block Transfer Write

Data

Word 13

Clock Time

Second

1/10 of Second

Data

Word 14

Clock Time

Hour

Minute

Drive Response –– Block Transfer Read

Warning Queue

Warning Queue Read Full