Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual
Page 191

7–45
Publication 1336 FORCE–5.13 –– September, 1998
This field:
Indicates:
Seconds
The seconds and tenths of milliseconds.
Date
The date of the month in ASCII.
Day
The day of the week, where 1 is Sunday and 7 is
Saturday.
Year
The number of the year. 1990 is referenced as 0.
Therefore, the year 1995 would return a value of 5.
Month
The month of the year, where 1 is January and 12 is
December.
If an error occurs in the block transfer, a value of -29952 is returned
in word 2 of the BTR response.
Example
In this example, the clock was read with a value of 2816 in word 2 of
the BTW. The BTR response indicated a successful read with a
value of 2816 in word 2.
•
Word 4 indicated a changing value for seconds.
•
The Hour value 0E indicates hour 14 of a 24 hour clock, or 2 pm.
The minute value 0A indicates 10, or 12:10 pm.
•
The Date of 17 in ASCII is the 23
rd
and the 5
th
day of the month,
or Thursday.
•
The Year 05 is 1995.
•
The Month of 02 is February.
1
0
N10:10
2
3
4
5
6
7
8
9
N10:90
BTW
Data File
BTR
Data File
Data Format
0
0
7681
3
0
2816
2816
3594
5893
1282
N10:90
0E\01 0E\0A 17\05 05\02
S\.1S
Hr\Min Date\Day Yr\Mth
ASCII Display Values
Real Time Clock Data Read
(continued)