6–13

Publication 1336 FORCE–5.13 –– September, 1998

306

Channel B LED State

[ChB LED State]

ChB LED State displays the current LED state for
channel B. The LED states correspond to LEDs
D13, D14, and D15 on the PLC Communications
Adapter Board.

Parameter Number

306

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

5

File – Group

Diagnostics – Info

Enums

0 = Off

1 = Red

2 = Green

3 = Yellow

4 = Flash Green

5 = Flash Red

307

PLC Communications Board Status

[PLC Comm Status]

PLC Comm Status displays the status of the PLC
Communications Adapter Board. You can use this
parameter to determine if no fault occurred, or if a
warning, soft fault, or hard fault occurred.

Parameter Number

307

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

3

File – Group

Diagnostics – Info

Enums

0 = No Faults

1 = Drv Warning

2 = Drv Soft Flt

3 = Drv Hard Flt

309

Language Select

[Language Sel]

You can use Language Sel to choose the language
you want the PLC Communications Adapter Board
to use for parameter and fault display text.
Currently, only English is available.

Parameter Number

309

Parameter Type

Read/Write, Non–Linkable Sink

Display Units / Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

1

File – Group

Startup – Drive Data Group

Diagnostics – Info

Enums

0 = English

1 = Alternate Language (not currently available)

314

Data Input A1

[Data In A1]

Data In A1 contains the first image word from the
SCANport output image table.

Parameter Number

314

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – SCANport I/O

315

Data Input A2

[Data In A2]

Data In A2 contains the second image word from the
SCANport output image table.

Parameter Number

315

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – SCANport I/O

316

Data Input B1

[Data In B1]

Data In B1 contains the third image word from the
SCANport output image table.

Parameter Number

316

Parameter Type

Read Only, Source

Display Units / Drive Units

None

Factory Default

0

Minimum Value

–32767

Maximum Value

+32767

File – Group

Communications I/O – SCANport I/O

Advertising