Example, Setup data full – Rockwell Automation 1336T PLC Comm. Adapter, Series B, FRN 2.xx-3.xx User Manual

Page 210

Advertising
background image

7–64

Publication 1336 FORCE–5.13 –– September, 1998

Trend Output Parameter specifies the sink parameter number that the
Trend Output parameter is linked to.

Example

In this example, a Trend 1 is set up to sample Velocity Feedback
(parameter number 101). The trend triggers when Velocity Feedback
is greater than 1750 rpm (an internal constant of 4096). When the
trigger condition is true, 400 more samples are taken (at a rate of 12
milliseconds each) before the trend stops. The output data is then
transferred to Analog Output 1 after the trend stops.

1

0

N10:10

2

3

4

5

6

7

8

9

N10:20

BTW
Data File

Data Format

4096

0

0

101

15

101

–28670

4096

0

387

400

1

6

0

0

N10:90

BTR
Data File

4096

3

4098

Setup Data Full

(continued)

Advertising