Setting decode parameters – Rockwell Automation 2755 AdaptaScan Software User Manual
Page 105

7–6
Publication 2755-838
The Decoder dialog configures decoding functions and is opened by
selecting the Decoder button on the main Project window.
Opens Used By Dialo
Opens More Dialog
Capture Count
Specifies the number of identical valid scans that must be decoded
for a valid read. Enter a value from 1 to 8. Use the default value of
2 for most applications.
Bar Code Label
Specifies the label setup the Reader is to decode. If none are defined,
you can select the Label button to open the Labels dialog.
Triggered By
Specifies the trigger source to initiate decoding. The trigger is
defined by the Reader name and type of trigger input.
Self-Triggered
When selected, decoding occurs continuously. Use the Inter-Symbol
No-Read Count (see page 7–9) to prevent multiple decodes of the
same symbol.
Note: When using Self-Triggered, increase the capture count to
greater than 2 (we recommend a value of 5 or 6).
Setting Decode Parameters