Scan adjustments – Rockwell Automation 2755 AdaptaScan Software User Manual
Page 77

5–3
Publication 2755-838
Online adjustments can affect the width and location of the scan
beam. Use these adjustments to make minor changes to an
application, not to compensate for improper installation.
See the AdaptaScan User Manual for descriptions of Usable Beam
Width, Scan Angles, Skew/Pitch/Tilt and Apparent Element Width.
•
Scan Width – adjusts beam width.
Scanner
Optical Scan Angles➀
2755-SN3
22
_ to 72_
2755-SN5
20
_ to 50_
2755-SN8
18
_ to 30_
➀
Usable scan angle is 80% of the optical scan angle.
•
Elevation (linear scanning only) – adjusts the vertical angle at
which the scan beam exits the Reader.
Elevation can be adjusted
10_ from center line.
Center Line
Variable
•
Upper and Lower Angles (raster scanning only) – adjusts the
high and low raster angles. The range for each angle is 10 to
-10
_. The lower scan angle must be equal to or less than the
upper scan angle.
Lower Scan Angle –10
_
from center line.
Center Line
Upper Scan Angle +10
_
from center line.
•
Flyback (raster scanning only) – quickly returns the scan beam
from the lower raster angle to the upper raster angle.
Flyback
Scan Adjustments