6–13
Publication 2755-838
UPC-A, UPC-E, EAN-8, EAN-13
Open the UPC and EAN dialogs by highlighting the symbology in
the Symbologies dialog and then selecting the Edit button.
Supplements
Select:
To:
2
Enable decoding of 2 character supplements. Both the primary
code and supplement are required for a valid read.
5
Enable decoding of 5 character supplements. Both the primary
code and supplement are required for a valid read.
2 and 5
Enable decoding of both 2 and 5 character supplements. Both
the primary code and supplement are required for a valid read.
Auto
Enable the Reader to decode labels with or without supple-
ments. Just the primary code is required for a valid read.
Expand (UPC-E Codes Only)
When selected, bar code data is transmitted in a 12 digit (expanded)
format. If Expand is not selected, data is sent in a 6 digit
(compressed) format.
☞